PD-L1 SP142 FDA (TECENTRIQ®) for NSCLC

Code
APH-PDSP-01AX
Test
Active-Compendium
88360 x1
Clinical
Oncology,Pathology
<b>Preferred specimen (FFPE block):</b><br>
A formalin-fixed, paraffin-embedded (FFPE) tissue block is the preferred specimen type. Use 10% NBF fixative; do not use zinc or mercury fixatives.<br>

<b>If submitting slides (instead of a block):</b><br>
Submit the following. All slides cut at 4-5 microns. Please use positively-charged slides and 10% NBF fixative.<br>
<span style="margin-left: 20px;">H&amp;E slide: One (1) unbaked, unstained slide for H&amp;E staining (required)</span><br>
<span style="margin-left: 20px;">Cut Slides: Two (2) positively charged unstained slides for each IHC test/antibody ordered</span><br>

<b>PD-L1 SP142 evaluation:</b><br>
Tissue submitted must have &gt;50 viable tumor cells present.<br>

<b>Specimen identification:</b><br>
Block and slide identifiers should be clearly written and match exactly with the specimen ID and specimen labeling as noted on the requisition.
Flag Active
True
Orderable Test Description
<p>The VENTANA PD-L1 (SP142) Assay is a qualitative immunohistochemical assay using rabbit monoclonal anti-PD-L1 clone SP142 intended for use in the assessment of the PD-L1 protein in formalin-fixed, paraffin-embedded (FFPE) non-small cell lung cancer (NSCLC) tissue on a VENTANA BenchMark ULTRA instrument. Evaluation is based on either the proportion of tumor area occupied by PD-L1 expressing tumor-infiltrating immune cells (% IC) of any intensity or the percentage of PD-L1 expressing tumor cells (% TC) of any intensity. Primary or metastatic NSCLC tissues may be submitted. Stain-only (tech-only) testing is available to clients who have completed the test kit manufacturer's online interpretation training.</p>
Orderable Turn Around Time
1-2 Days
Meta Description
The VENTANA PD-L1 (SP142) Assay is a qualitative IHC assay using rabbit monoclonal anti-PD-L1 clone SP142 intended for use in the assessment of the PD-L1 protein in FFPE non-small cell lung cancer (NSCLC) tissue on a VENTANA BenchMark ULTRA instrument.
Orderable Biomarkers
NY Approved
True
Orderable Biomarkers JSON
{"Immunohistochemistry (IHC)": {"Expression": ["PD-L1"]}}
Keywords string
PD-L1, PD-L1 SP142 FDA (TECENTRIQ®) for NSCLC, SP142, FDA, TECENTRIQ, NSCLC PD-L1 SP142 FDA (TECENTRIQ®) for NSCLC
Title URL
pd-l1-sp142-fda-tecentriq-for-nsclc
TAT Details

Global: 2 Days
Tech-Only (stain only): 24 Hours

Storage and transportation

Slides may be stored at room temperature; transport with cold pack, making sure cold pack is not in direct contact with specimen.
NYS Clients: Please provide Date and Time of Collection.