MSH2

Code
APH-MSTX-01AX
Test
Active-Compendium
88342 x 1 or 88341 x 1; 88360 x 1; 88361 x 1
Clinical
Pathology
<b>Preferred specimen (FFPE block):</b><br>
A formalin-fixed, paraffin-embedded (FFPE) tissue block is the preferred specimen type. Use 10% NBF fixative; do not use zinc or mercury fixatives.<br>

<b>If submitting slides (instead of a block):</b><br>
Submit the following. All slides cut at 4-5 microns. Please use positively-charged slides and 10% NBF fixative.<br>
<span style="margin-left: 20px;">H&amp;E slide: One (1) unbaked, unstained slide for H&amp;E staining (required)</span><br>
<span style="margin-left: 20px;">Cut Slides: Two (2) positively charged unstained slides for each IHC test/antibody ordered</span><br>

<b>Specimen identification:</b><br>
Block and slide identifiers should be clearly written and match exactly with the specimen ID and specimen labeling as noted on the requisition.
Flag Active
True
Orderable Test Description
Human mismatch repair protein 2 (MSH2) is involved in the initial recognition of mismatched nucleotides during the post replication mismatch repair process. Loss of MSH2 function leads to the accumulation of replication errors, which in turn may be responsible for the multiple mutations required for multistage carcinogenesis. Mutations in MSH2 gene is linked to hereditary nonpolyposis colon cancer and to sporadic cancers which exhibit microsatellite instability.
Orderable Turn Around Time
1-2 Days
Meta Description
Human mismatch repair protein 2 (MSH2) is involved in the initial recognition of mismatched nucleotides during the post replication mismatch repair process.
Orderable Biomarkers
NY Approved
True
Orderable Biomarkers JSON
{"Immunohistochemistry (IHC)": {"Expression": ["MSH2"]}}
Keywords string
MSH2, MSH2 expression, MSH2 IHC, MMR MSH2
Title URL
msh2
TAT Details

Image Analysis for Global: 2 Days
Image Analysis for (Tech-Only): 2 Days
Tech-Only (stain only): 24 Hours

Storage and transportation

Slides may be stored at room temperature; transport with cold pack, making sure cold pack is not in direct contact with specimen.
NYS Clients: Please provide Date and Time of Collection.